Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13604356

- Product Categories
- Friendly Links
- home > Supply > Learning remote detection machines, typewriters learning remote, remote control, dynamic current testing machine, remote control quiescent current testing machine, Long Shuo intelligent remote control detector, Long Shuo universal remote control detection machines, television set-top box remote detection machines, air conditioning, remote control detector , CCD detector screen, universal remote control tester,
Learning remote detection machines, typewriters learning remote, remote control, dynamic current testing machine, remote control quiescent current testing machine, Long Shuo intelligent remote control detector, Long Shuo universal remote control detection machines, television set-top box remote detection machines, air conditioning, remote control detector , CCD detector screen, universal remote control tester,
Information Name: | Learning remote detection machines, typewriters learning remote, remote control, dynamic current testing machine, remote control quiescent current testing machine, Long Shuo intelligent remote control detector, Long Shuo universal remote control detection machines, television set-top box remote detection machines, air conditioning, remote control detector , CCD detector screen, universal remote control tester, |
Published: | 2015-01-29 |
Validity: | 0 |
Specifications: | 1000 * 930 * 1450 |
Quantity: | 10000.00 |
Price Description: | |
Detailed Product Description: | 1) Click on the main striking soft head: The use of lightweight aluminum alloy one-hit nod, which can at most pressing three buttons. A stable, easy adjustment features; 2) remote control clamping device: when the remote control can be adjusted according to the size of the adapter into the space, use soft cover positioning column surrounded to prevent remote control in the clamping pressure shocks cause scratches; 3) Remote control powered analog fixture: the power-jigs adjusted for multi-directional remote control of different customers, power fixture is divided into four types: parallel type, vertical type, the word type, word single mouth; gas powered battery core material for the manufacture of copper (conductive ability, quality assurance) seals are imported products, stable easy to leak; 4) Multi-function infrared signal receiver: for receiving infrared Infrared remote control code waveform of each key, the data through a special multifunction board computer into a digital signal into the actual waveform displayed on the screen, and with the product code has been entered and qualified waveform is compared to determine the tested products data encoding, if the carrier frequency qualified 5) before adjusting plate bracket: For varying in thickness layer of the remote control, front pallet can be adjusted according to the thickness, enabling remote control infrared receiver launch tube alignment, easy deviation, and make the data more accurate; 6) after adjusting plate bracket: mainly in long bias play a supporting role for the remote control, hold the tail to avoid shaking occurs during the test, the test result deviation; 7) Remote Control Fixture bracket: The board is made of red bakelite, versatile modular design, easy adjustment and stable and durable; and versatile signal reception by the board, the former care unit, clamping fixture, after care unit plus a number composed of analog electrical fixture fixtures, semi-finished another PCB test fixtures just replace the device can be powered automatic test function; II. The program's interface 4, this page is the program's interface, intuitive display test results. This page has a diagram of a remote control button. One point above represents the actual remote control button above points. After the testing machine is pressed, the detected waveform consistent with the range of requirements. The key point is displayed in green. If you do not comply with that, the key point is shown in red. 5, the detected data show "dynamic current" "quiescent current" "emission intensity" "Waveform degree of difference." When the data does not meet the set here circumference, shown in red background. 6, "OK" and "NG" when the remote control test, consistent with the index is completed when a remote control test. Will show "OK", but as long as there is a button on the display when not in symbol "NG". 7, when the "Select Program" button These functions can only be landed administrators can use. Used to select the program you want to test what a remote control 8, "Programming" When the function is a major test for the new page with a remote control machine debugging. Administrators need to log back with details said. 9, "User Login" want two main user groups, "operator": operations workers use; "administrator": by trained technical staff. Leader, with its permission, you can change test parameters, system commissioning, new construction and so on. The initial administrator password is "1234" 10, the running status area, it can see the machine running the working platform and the next will be running the working platform. 11, test control area "alarm Open": to open the alarm function, when there are arguments over the range, the buzzer sounded "beep" tone green. 12. "Run" function to pause the machine running some function. Click once to "suspend" state. Click again to "run" state. 13, "Back" when the machine is paused state, click on the "Back", you can view the test does not pass the keys back to check the situation. 14, after the step on to view the status of the machine, let the machine continue down, you should cancel the paused state, then click "Next" to continue down the machine. 15, production statistics. 16, the waveform is displayed in the test control area, the white part underneath the blank area. The first part is already done for the display contrast with the input waveform, and the lower parts of the keys for the current waveform display. Second, the programming interface programming interface Pictured above, do the following detailed description of each function, the program management 1.1 "Open" to open an existing project on the remote control panel, the starting point for alignment with the parameters set. 1.2 "New" to create a new project panel 1.3 "Save" to create a new project after project or set parameters, you need to click Save, the set parameters to work. 1.4 "Save As" to create a new and similar projects already exist when the original, so quickly, just a small part of the changes. 2, the key editor 2.1 "add button" Add a button 2.2 "copy button" in the editing area to add a remote control panel buttons on the remote control panel inside the editing area 2.3 "Insert button" on the remote control panel editing area, has edited the project, insert a button 2.3 "delete button" in the editing area to delete a remote control panel buttons 3, remote control panel to set the width of the length is set to 3.1, where the remote control panel to change the length, width. 3.2 Load picture click will bring up a file selection dialog box, select a remote control panel to scan images displayed in the project editor. You can then follow, key points on the picture, create a new project. 3.3 interface display magnification here is to control the remote control panel in the fixed line interface display magnification, if not fully displayed in the operation of the interface to four remote control panel, you can adjust the magnification here, reduction ratio. 4, the voltage setting area 4.1 If you need to test the voltage level when the remote control settings, you need to change here, click on the front of the selection box. Low Voltage: 2.20V voltage: 3.0V High Voltage: 3.7V If you need additional voltage settings, click on the custom voltage selection box. At this point you can use the mouse to pull the slider to the desired voltage; 4.2 set when the polarity of the battery cell polarity and not on the remote control, you can choose to change the polarity of the battery at. 5, the key settings area 5.1 Key number: that is the key number on the remote control panel, the track number order is executed by the machine. Recommend remote control button press Z-row exclusive method, which saves time. 5.1.1 skip button, when some buttons do not need to test, or no signal, you can choose to skip. 5.1.2 When one button, you need to enter the special function keys with the other when needed, select contains sub-key, you can point to open the back button to pop up the Add button to add sub-key dialog 5.1.2.1 numbers need to press the button number, time, etc. eleven settings, set up, you can click on the application. 5.2 abscissa X: X-axis coordinate display 5.3 ordinate Y: Y-axis coordinate display 5.4 Z-axis compensation: here is possible to fill out the data, mainly in order to facilitate the testing time, and some remote control buttons are not at the same height in the plane , then you can use this to set the height of the Z-axis motion compensation. 5.5 Key Hold: This is the key, you need to wait a long time, where the number of time to wait to fill in milliseconds (ms) 1000mS = 1S 5.6 lift waiting: waiting time after the lift. 5.7 key settings: Click the drop-down box back, you can select a signal, no signal, etc. 5.8 Test Action Settings: 5.8.1 Static current: In the first few buttons on the hook here, it means that when the machine is running to the button, this test action. 5.8.2 Dynamic Current: In the first few buttons on the hook here, it means this button when the machine is running to carry out this test action. 5.8.3 emission intensity: In the first few buttons on the hook here, it means this button when the machine is running to carry out this test action. 5.8.4 waveform test: Each test button should be put on the hook here. No key waveforms can not. 5.8.5 Coding learning: This is the time to learn shaped remote control. When you press this button, wait for the process of learning to use. Procedure code used machine tools hair. 5.8.6 Auxiliary button: tests needed to assist button keys, put on the election here. 6, axial control area starting save 6.1 Y1 axis: To the left of the platform Y2 axis: Z axis to the right of the platform: up and down movement of the axes X axis: left and right movement of the shaft with the mouse, click the button above, the corresponding bit in the axis a short distance on the corresponding movement direction. If the long-distance movement, then in the corresponding axial direction button, click on the left mouse button is released. 6.2 Added the first key point when you start the design process after the panel, in order to facilitate the design of the program. Calibrate the starting point. Movement behind the buttons and axis position can track order. Click on the left to save after calibration starting point. 6.3 Z-axis movement height figures in the text box to fill in the process when the figures. Generally located about 700, double-click the button on the remote control panel design, Z-axis can be done click action. You can see, there is no record type code display area. 7, manually operated clamping area of ??about 7.1: After clicking once, the corresponding action clamp solenoid valves. The corresponding button can also become green. Power-about 7.2: After clicking once on electric solenoid valves corresponding action. The corresponding button can also become green. 7.3 starting left and right starting point: Click, click on the appropriate head will come to the starting position, provided there is calibrated starting point. 8, the quiescent current range settings area 8.1: Range 0 ~ 50uA 8.2 Dynamic Current: 0 ~ 50mA 8.3 range emission intensity: Range 0 ~ 1200mV 8.4 degree difference waveform: Commissioning read 0 ~ 40% 8.5 various data click on one of the first choice After an option, at the point the Read button. This four-channel data is displayed in the text box, respectively, CH1, CH2, CH3, CH4. 9. Other features 9.1 movement speed settings: speed Suggestion: Start Speed: 9550 Maximum speed: 60000 Acceleration: 250000 deceleration: 250000 9.2 Test Setup Action 9.2.1 Test mode manual mode test: After detection is a platform, To test the other side of the platform, you need to manually press the Run button to perform the automatic mode test: In this mode, a continuous back and forth on both sides of the platform test. You can fill in the middle of the pause time interval in milliseconds mS. 9.2.2 Adverse retest the key at the first test, there may be adverse conditions (may be subject to interference), then re-test to confirm. 9.3 IO IO status confirmation status confirmation is used to confirm the commissioning of each functional board input and output are normal. 10, the waveform input: 10.1.1 When the project after the panel completed, the starting point is also calibrated, a key point to point, and then play the next election. Recorded and then point code, the machine will start automatically recorded code. When finished, save, return to the test. |
Admin>>>
You are the 6883 visitor
Copyright © GuangDong ICP No. 10089450, Dongguan City, Long Shuo Automation Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 6883 visitor
Copyright © GuangDong ICP No. 10089450, Dongguan City, Long Shuo Automation Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility